Model |
24V 1.5A |
| Output |
DC Voltage |
24V |
| Voltage Range |
23.8V-24.2V |
| Rated Current |
0-1.5A |
| Rated Power |
36W |
| Ripple & Noise |
200mVp-p |
| Input |
Voltage Range |
100-240VAC |
| Frequency Range |
50 – 60Hz |
| Overshoot at turn-on/ turn-off |
Any overshoot at turn on/ turn off shall be less than 110 % of rated output voltage. |
| Full Load Efficiency(Typ.) |
80% |
| Input Current Limiting |
The input current should < 1.2A, under Min. AC input and full loads. |
| Inrush current |
≤50A |
| Protection |
Overshoot at turn-on/ turn-off |
Any overshoot at turn on or turn off shall be less than 110 % of rated output voltage. |
| Short Circuit |
An output short circuit will automatically enter the protected status .The power supply will protect without damage to overseers of to the unit (components, connectors, etc) under the protection of process. |
| Overshoot at turn-on/ turn-off |
Any overshoot at turn on/ turn off shall be less than 110 % of rated output voltage. |
| Over Voltage |
Min 11.5V, Max 12.5V |
| Input Current Limiting |
The input current should < 1.2A, under Min. AC input and full loads. |
| Over Current |
The power supply shall meet the limitation requirement Min 3.2A, Max 3.8A without any damage, the unit shall recover the function after the protection is removed. |
| Over Voltage |
Min 11.5V, Max 12.5V |
| Over Temperature |
100°C±10°Cshut down o/p voltage, re-power on to recover |
| Hold up Time |
≥10mS at 100Vac, the output loading should be set up with full load during the test. |
| Start up Time |
≤3S at 100Vac, the output loading should be set up withfull load during the test. |
| Environment |
Burn-in and Life test |
RS shall discuss with customer to maker sure the power in house Burn-In and life test procedures. |
| Working TEMP.,Humidity |
0~+40°C,20~85%RH |
| Storage TEMP.,Humidity |
-20~+75°C,10~90%RH. |
| Reliability |
MTBF no less than 10000 hours (25 °C, Full load and rated voltage input, MIL-HDBK-217F) |
| Insulation Resistance |
Primary to Secondary: 10 Meg. Ohms min. 500VDC . Primary to P.G: 10 Meg. Ohms min. 500VDC |
| Safety Requirement |
Dielectric Strength |
Primary to Secondary: 1500VAC, < 5mA, 3s |
| Withstand Voltage |
I/P-O/P:1.5KVAC |
| Standard |
CE ,FCC Mark,Meet IEC60950,EN55022 standard requirement |
Reviews